| Sign In | Join Free | My benadorassociates.com | 
              
  | 
      
Brand Name : MEASTEK
Model Number : MCTH400A
MOQ : 1
Payment Terms : T/T,Western Union,MoneyGram
Delivery Time : 5-8 work days
Model : MCTH400A
Maximum current : 400A
Accuracy : 0.01%
Bandwidth : 100KHz
Current transfer ratio : 1:2000
MCTH400A High-precision Current Sensor 0.01% Accuracy Wideband 100kHz Laboratory-grade Isolation Measurement Applicable To Medical new Energy
1. Basic Parameters
Maximum current: 400A (DC/RMS), accuracy of 0.01%, bandwidth of 100kHz, suitable for DC, AC and irregular waveform measurement.
2. High sensitivity and low loss
Current transfer ratio 1:2000, extremely low insertion loss, noise ≤±0.004μA, suitable for laboratory precision instruments or battery pack monitoring.
3. Core technology support
Adopting excitation flux closed-loop control and temperature control compensation technology, the temperature drift is extremely small, ensuring stable operation in the range of -10℃~+70℃.
4. Safety protection design
Power frequency withstand voltage 5kV, insulation resistance>2000MΩ@500V, support overload Error signal alarm to ensure equipment safety.
5. Application scenarios
Laboratory current calibration, medical equipment (such as MRI), small industrial motor drive and new energy photovoltaic system.
Specifications
| Model | Maximum current | Accuracy | Bandwidth | Current transfer ratio | |
| DC | RMS | ||||
|   MCTH400A  |    400A  |    400A  |    0.01%  |    100KHz  |    1:2000  |  
Electrical properties
| Item | Symbol | Test Conditions | Minimum | Nominal | Maximum | Unit | 
| Maximum continuous DC current |   IPN_DC  |    -  |    400  |    -  |    1000  |    Adc  |  
| Corresponding measurement current range (Arms) |   IP  |    -  |    400  |    -  |    1000  |    Aac  |  
| Primary-secondary conversion ratio |   KN  |    -  |    1:2000  |    -  |    1:2000  |    -  |  
| Rated output current (mArms) |   Isn  |  Primary rated current |   200  |    -  |    500  |    mA  |  
| Power supply voltage (±5%) |   Vc  |    -  |    -  |    ±15  |    -  |    V  |  
| Power consumption |   Ic  |    -  |    35mA +Is  |    -  |    35mA +Is  |  mA | 
| Load resistance (@Vc=±15V) |   RL  |    -  |    ≤50Ω(@Ip=DC400A)  |    -  |    ≤50Ω(@Ip=DC1000A)  |    Ω  |  
| Secondary resistance |   Rs  |    -  |    ≈15  |    -  |    ≈15  |    Ω  |  
| Power frequency withstand voltage (50HZ, 1min) |   Vd  |    -  |    -  |    5  |    -  |    KV  |  
| Insulation resistance |   Ri  |    -  |    -  |    >2000MΩ@DC500V  |    -  |    Ω  |  
Accuracy Measurement
| Item | Symbol | Test Conditions | Minimum | Nominal | Maximum | Unit | 
| Accuracy (@Ta = +25℃) |   XG  |  Input DC, full temperature range |   -  |    -  |    0.01  |    %  |  
| Linearity error |   EL  |  Full range |   -  |    -  |    0.005  |    %  |  
|   Offset current (@Ta =+25℃)  |    Ioff  |  Full temperature range |   -  |    -  |    ≤|±0.004|μA  |    μA  |  
| Response time |   Tr  |  di/dt=100A/μs, rise to 90% IPN |   -  |    -  |    ≤1  |    μs  |  
| Following speed |   di/dt  |    -  |    >100  |    -  |    >100  |    A/μs  |  
| Frequency range |   f  |    -  |    -  |    -  |    100  |    kHz  |  
General Features
| Item | Symbol | Test Conditions | Minimum | Nominal | Maximum | Unit | 
| Operating temperature range |   Ta  |    -  |    -10  |    -  |    +70  |    ℃  |  
| Storage temperature range |   Ts  |    -  |    -25  |    -  |    +80  |    ℃  |  
| Working humidity (no condensation) |   Hw  |    -  |    20  |    -  |    90  |    %  |  
| Weight |   W  |    -  |    -  |    ±600  |    -  |  g | 
| Execution standard |   St  |    EN50178  |  ||||
| Casing material |   Encl  |  Compliant with UL94-V0 | ||||
Structure Diagram

|   Basic dimensional error  |    ±0.2mm  |  
|   Primary aperture  |    Φ40.5mm  |  
|   Disc installation  |    Bottom:4 x Φ4mm,2 x Φ5mm Side:4 x Φ5mm  |  
|   Output terminal  |    DB9 MALE  |  
| 
                                             | 
                